Versa Appliance
Introduction
Versa Appliances are secure SD-WAN and edge routing platforms that unify networking and security, enabling scalable, cloud-managed connectivity and advanced traffic steering for distributed enterprise environments
Getting Started
Compatibility
Versa Appliance O11ySource supports SNMP versions v1, v2c and v3.
Data Collection Method
Versa Appliances provide data collection through SNMP, Syslog, and IPFIX/NetFlow exports on VOS devices, complemented by REST APIs in Versa Director and Analytics. This enables comprehensive collection of system, flow, and security telemetry for seamless integration with NMS, SIEM, and observability platforms
Prerequisites
Dependent Configuration
To configure this O11ySource, create a 'credential' of type 'snmp' under the 'Definition' tab.
Inputs for Configuring Data Source
- Group Name: This field is for grouping devices for SNMP polling, making it easier to manage devices with common characteristics or within the same network segment.
- Number of Retries: Number of times the system should reattempt polling if the initial attempt fails. Default is set to 7 retries
- Timeout Duration: Specify how long the system should wait for a response from a device before considering the attempt unsuccessful. Default timeout is 5 seconds
- Device: Details needed to collect health data from the devices using SNMP
- Device IP: Enter the IP address of the device.
- SNMP Credential: Select the SNMP credential from the dropdown list that corresponds to this device.
- Vendor: Select the vendor of the device from the dropdown list
- Model: Select the model of the device from dropdown list.
- MIB Groups: Define what MIBs to be queried and how often
- MIB Group: Default: 'ALL_SUPPORTED_MIB_GROUPS'.
- Interval: Default: 360 seconds
Firewall Requirement
To collect data from this O11ySource, ensure the following ports are opened:
| Source IP | Destination IP | Destination Port | Protocol | Direction |
|---|---|---|---|---|
| vuSmartMaps IP | IP address of the SNMP device | 161* | UDP | Outbound |
*Before providing the firewall requirements, please update the port based on the customer environment.
Configuring the Target
Configure SNMP on Versa Appliances and grant SNMP access permissions to vuSmartMaps designated IP address.
Configuration Steps
Enablethe O11ySource.- Select the sources tab and press the
+button to add a new instance that has to be monitored. - Provide the required configurations:
- *Resource Name
- *Period (in seconds)
- *Credential
- *Resource ID
- Click
Saveto close the data source window.
Metrics Collected
| Name | Description | Data Type |
|---|---|---|
| @timestamp | Timestamp string | String |
| Timestamp | Timestamp with precision | DateTime64 |
| bu_id | Business unit ID | LowCardinality(String) |
| tenant_id | Tenant ID | LowCardinality(String) |
| host | Host IP Address | IPv4 |
| target | Target system | String |
| Device IP | Device IP Address | IPv4 |
| Data Type | Type of data | LowCardinality(String) |
| type | Event type | LowCardinality(String) |
| vendor_name | Vendor name | LowCardinality(String) |
| device_type | Device type | LowCardinality(String) |
| period | Time period | Int32 |
| system_name | System name | String |
| name | Name of the object | String |
| index | Index value | String |
| vublock_name | VuBlock Name | String |
| topic_of | Topic associated | String |
| CPU Utilization | CPU Utilization | Float64 |
| CPU Name | CPU Name | LowCardinality(String) |
| Memory Utilization | Memory Utilization | Float64 |
| Uptime | System Uptime | UInt64 |
| Uptime in seconds | System Uptime in Seconds | Float64 |
| Total Memory | Total Real Memory | UInt64 |
| Used Memory | Active Real Memory | UInt64 |
| Total Disk Size | Disk Size | UInt64 |
| Free Disk Space | Disk space available in the partition | UInt64 |
| Disk Used Percentage | Disk Used Percentage | Float64 |
| Temperatue Value | Temperature Value | Int64 |
| Total Memory | Total Real Memory | UInt64 |
| Used Memory | Active Real Memory | UInt64 |
| Free Memory | Free Real Memory | UInt64 |